A Closer Look Home Inspection Services
|
|
PROFESSIONAL CERTIFIED HOME INSPECTIONS OF WEST CENTRAL FLORIDA, TAMPA, HILLSBOROUGH,PINELLAS AND POLK COUNTIES
|
 |
A Closer Look Home Inspection Services
Professional Certified Home Inspections
Po Box 2791, Riverview, Florida 33568
Tel: 813 625 2421 Mobile: 813 625 2421
WWW.ACLOSERLOOKHOMEINSPECTIONSERVICES.COM SW1919@AOL.COM
CONFIDENTIAL INSPECTION REPORT
PREPARED FOR:
_______________________________________________________________
INSPECTION ADDRESS
INSPECTION DATE
5/16/2006 9:00 am to 12:30 pm
This report is the exclusive property of the Inspection Company and the client whose name appears
herewith, and its use by any unauthorized persons is prohibited.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 1
GENERAL INFORMATION
Inspection Address:
Inspection Date: 5/16/2006 Time: 9:00 am to 12:30 pm
Weather: Clear and Dry - Temperature at time of inspection: 75 Degrees
Humidity at time of inspection: 75%
Inspected by:
Structure Type: Masonry Block
Furnished: No
Number of Stories: One
Structure Style: Modern
Structure Orientation: South
Estimated Year Built: 2000
Unofficial Sq.Ft.: 2500
People on Site At Time of Inspection: Buyer(s)
Buyer's Agent
PLEASE NOTE:
This report is the exclusive property of A Closer Look Home Inspection Services and the client whose
name appears herewith, and its use by any unauthorized persons is strictly prohibited.
The observations and opinions expressed within this report are those of A Closer Look Home
Inspection Services and supercede any alleged verbal comments. We inspect all of the systems,
components, and conditions described in accordance with the standards of NACHI, and those that we
do not inspect are clearly disclaimed in the contract and/or in the aforementioned standards. However,
some components that are inspected and found to be functional may not necessarily appear in the
report, simply because we do not wish to waste our client's time by having them read an unnecessarily
lengthy report about components that do not need to be serviced.
In accordance with the terms of the contract, the service recommendations that we make in this report
should be completed well before the close of escrow by licensed specialists, who may well identify
additional defects or recommend some upgrades that could affect your evaluation of the property.
Report File: mr web site
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 2
SCOPE OF WORK
You have contracted with A Closer Look Home Inspection Services to perform a generalist inspection in
accordance with the standards of practice established by Nachi. www.nachi.org
A copy of which is available upon request. Generalist inspections are essentially visual, and distinct from those
of specialists, inasmuch as they do not include the use of specialized instruments, the dismantling of
equipment, or the sampling of air and inert materials. Consequently, a generalist inspection and the subsequent
report will not be as comprehensive, nor as technically exhaustive, as that generated by specialists, and it is not
intended to be. The purpose of a generalist inspection is to identify significant defects or adverse conditions
that would warrant a specialist evaluation. Therefore, you should be aware of the limitations of this type of
inspection, which are clearly indicated in the standards. However, the inspection is not intended to document
the type of cosmetic deficiencies that would be apparent to the average person, and certainly not intended to
identify insignificant deficiencies.
Most homes built after 1978, are generally assumed to be free of asbestos and many other common
environmental contaminants. However, as a courtesy to our clients, we are including some well documented,
and therefore public, information about several environmental contaminants that could be of concern to you
and your family, all of which we do not have the expertise or the authority to evaluate, such as asbestos, radon,
methane, formaldehyde, termites and other wood-destroying organisms, pests and rodents, molds, microbes,
bacterial organisms, and electromagnetic radiation, to name some of the more commonplace ones.
Nevertheless, we will attempt to alert you to any suspicious substances that would warrant evaluation by a
specialist. However, health and safety, and environmental hygiene are deeply personal responsibilities, and you
should make sure that you are familiar with any contaminant that could affect your home environment. You can
learn more about contaminants that can affect you home from a booklet published by The environmental
Protection Agency, which you can read online at www.epa.gov/iaq/pubs/insidest.htm.
Mold is one such contaminant. It is a microorganism that has tiny seeds, or spores, that are spread on the air,
land, and feed on organic matter. It has been in existence throughout human history, and actually contributes to
the life process. It takes many different forms, many of them benign, like mildew. Some characterized as
allergens are relatively benign but can provoke allergic reactions among sensitive people, and others
characterized as pathogens can have adverse health effects on large segments of the population, such as the
very young, the elderly, and people with suppressed immune systems. However, there are less common molds
that are called toxigens that represent a serious health threat. All molds flourish in the presence of moisture,
and we make a concerted effort to look for any evidence of it wherever there could be a water source, including
that from condensation. Interestingly, the molds that commonly appear on ceramic tiles in bathrooms do not
usually constitute a health threat, but they should be removed. However, some visibly similar molds that form
on cellulose materials, such as on drywall, plaster, and wood, are potentially toxigenic. If mold is to be found
anywhere within a home, it will likely be in the area of tubs, showers, toilets, sinks, water heaters, evaporator
coils, inside attics with unvented bathroom exhaust fans, and return-air compartments that draw outside air, all
of which are areas that we inspect very conscientiously. Nevertheless, mold can appear as though
spontaneously at any time, so you should be prepared to monitor your home, and particularly those areas that
we identified. Naturally, it is equally important to maintain clean air-supply ducts and to change filters as soon
as they become soiled, because contaminated ducts are a common breeding ground for dust mites, rust, and
other contaminants. Regardless, although some mold-like substances may be visually identified, the specific
identification of molds can only be determined by specialists and laboratory analysis, and is absolutely beyond
the scope of our inspection. Nonetheless, as a prudent investment in environmental hygiene, we categorically
recommend that you have your home tested for the presence of any such contaminants, and particularly if you
or any member of your family suffers from allergies or asthma. Also, you can learn more about mold from an
Environmental Protection Agency document entitled "A Brief Guide to Mold, Moisture and Your Home," by
visiting their web site at: http://www.epa.gov/iaq/molds/moldguide.html/, from which it can be downloaded.
Asbestos is a notorious contaminant that could be present in any home built before 1978. It is a naturally
occurring mineral fiber that was first used by the Greek and Romans in the first century, and it has been widely
used throughout the modern world in a variety of thermal insulators, including those in the form of paper wraps,
bats, blocks, and blankets. However, it can also be found in a wide variety of other products too numerous to
mention, including duct insulation and acoustical materials, plasters, siding, floor tiles, heat vents, and roofing
products. Although perhaps recognized as being present in some documented forms, asbestos can only be
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 3
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
specifically identified by laboratory analysis. The most common asbestos fiber that exists in residential products
is chrysotile, which belongs to the serpentine or white-asbestos group, and was used in the clutches and brake
shoes of automobiles for many years. However, a single asbestos fiber is said to be able to cause cancer, and
is therefore a potential health threat and a litigious issue. Significantly, asbestos fibers are only dangerous when
they are released into the air and inhaled, and for this reason authorities such as the Environmental Protection
Agency [EPA] and the Consumer Product Safety Commission [CPSC] distinguish between asbestos that is in
good condition, or non-friable, and that which is in poor condition, or friable, which means that its fibers could
be easily crumbled and become airborne. However, we are not specialists and, regardless of the condition of
any real or suspected asbestos-containing material [ACM], we would not endorse it and recommend having it
evaluated by a specialist.
Radon is a gas that results from the natural decay of radioactive materials within the soil, and is purported to be
the second leading cause of lung cancer in the United States. The gas is able to enter homes through the voids
around pipes in concrete floors or through the floorboards of poorly ventilated crawlspaces, and particularly
when the ground is wet and the gas cannot easily escape through the soil and dispersed into the atmosphere.
However, it cannot be detected by the senses, and its existence can only be determined by sophisticated
instruments and laboratory analysis, which is completely beyond the scope of our service. However, you can
learn more about radon and other environmental contaminants and their affects on health, by contacting the
EPA or a similar state agency, and it would be prudent for you to enquire about any high radon readings that
might be prevalent in the general area surrounding your home.
Lead poses an equally serious health threat. In the 1920's, it was commonly found in many plumbing systems.
In fact, the word "plumbing" is derived from the Latin word "plumbum," which means lead. When in use as a
component of a waste system, it does not constitute a viable health threat, but as a component of potable water
pipes it would certainly be a health-hazard. Although rarely found in use, lead could be present in any home
build as recently as the nineteen forties. For instance, lead was an active ingredient in many household paints,
which can be released in the process of sanding, and even be ingested by small children and animals chewing
on painted surfaces. Fortunately, the lead in painted surfaces can be detected by industrial hygienists using
sophisticated instruments, but testing for it is not cheap. There are other environmental contaminants, some of
which we have already mentioned, and others that may be relatively benign. However, we are not
environmental hygienists, and as we stated earlier we disclaim any responsibility for testing or establishing the
presence of any environmental contaminant, and recommend that you schedule whatever specialist inspections
that may deem prudent before the close of escrow.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 4
Inspection Address: , ,
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
Exterior
With the exception of townhomes, condominiums, and residences that are part of a planned urban
development, or PUD, we evaluate the following exterior features: driveways, walkways, fences, gates,
handrails, guardrails, yard walls, carports, patio covers, decks, building walls, fascia and trim, balconies, doors,
windows, lights, and outlets. However, we do not evaluate any detached structures, such as storage sheds and
stables, and we do not water test or evaluate subterranean drainage systems or any mechanical or remotely
controlled components, such as driveway gates. Also, we do not evaluate landscape components, such as
trees, shrubs, fountains, ponds, statuary, pottery, fire pits, patio fans, heat lamps, and decorative or low-voltage
lighting. In addition, we do not comment on coatings or cosmetic deficiencies and the wear and tear associated
with the passage of time, which would be apparent to the average person. However, cracks in hard surfaces
can imply the presence of expansive soils that can result in continuous movement, but this could only be
confirmed by a geological evaluation of the soil.
Site & Other Observations
Landscaping Observations
Informational Conditions
We do not evaluate landscaping, but some of the trees need to be trimmed or pruned.
There are tree limbs overgrowing the residence that should be trimmed or monitored, to insure that they do not
impact of damage the roof or its components.
Grading & Drainage
General Comments
Informational Conditions
Water can be destructive and foster conditions that are deleterious to health. For this reason, the ideal property
will have soils that slope away from the residence and the interior floors will be several inches higher than the
exterior grade. Also, the residence will have roof gutters and downspouts that discharge into area drains with
catch basins that carry water away to hard surfaces. However, we cannot guarantee the condition of any
subterranean drainage system, but if a property does not meet this ideal, or if any portion of the interior floor is
below the exterior grade, we cannot endorse it and recommend that you consult with a grading and drainage
contractor, even though there may not be any evidence of moisture intrusion. The sellers or occupants will
obviously have a more intimate knowledge of the site than we could possible hope to have during our limited
visit, however we have confirmed moisture intrusion in residences when it was raining that would not have been
apparent otherwise. Also, in conjunction with the cellulose material found in most modern homes, moisture can
facilitate the growth of biological organisms that can compromise building materials and produce mold-like
substances that can have an adverse affect on health.
Interior-Exterior Elevations
Informational Conditions
There is an adequate difference in elevation between the exterior grade and the interior floors that should
ensure that moisture intrusion would not threaten the living space, but of course we cannot guarantee that.
Flat & Level Pad
Informational Conditions
The residence is situated on a flat level pad, which would typically not need a geological evaluation. However,
inasmuch as we do not have the authority of a geologist you may wish to have a site evaluation.
Drainage Mode
Informational Conditions
Drainage on this property is solely dependant on soil-percolation and hard surfaces, and there are no roof
gutters or area drains. Such conditions are not ideal, and water may pond at various points during prolonged
rains. Therefore, you may wish to have a specialist evaluate, but we did not see any evidence of moisture
contaminating the living space.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 5
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
Drainage Swales
Informational Conditions
The drainage swales are clear and clean, and should be kept clean for the general maintenance of the property.
House Wall Finish
House Wall Finish Type
Informational Conditions
The house walls are finished with stucco.
House Wall Finish Observations
Informational Conditions
There are typical cracks in the stucco, which you should view for yourself. All cracks result from movement,
and are structural in that respect, but the vast majority of them have only a cosmetic significance. However,
you may wish to have this confirmed by a specialist.
Exterior Components
General Comments
Informational Conditions
It is important to maintain a property, including painting or sealing walkways, decks, and other hard surfaces,
and it is particularly important to keep the house walls sealed, which provide the only barrier against
deterioration. Unsealed cracks around windows, doors, and thresholds can permit moisture intrusion, which is
the principle cause of the deterioration of any surface. Unfortunately, the evidence of such intrusion may only
be obvious when it is raining. We have discovered leaking windows while it was raining that may not have been
apparent otherwise. Regardless, there are many styles of windows but only two basic types, single and
dual-glazed. Dual-glazed windows are superior, because they provide a thermal as well as an acoustical
barrier. However, the hermetic seals on these windows can fail at any time, and cause condensation to form
between the panes. Unfortunately, this is not always apparent, which is why we disclaim an evaluation of
hermetic seals. Nevertheless, in accordance with industry standards, we test a representative number of
unobstructed windows, and ensure that at least one window in every bedroom is operable and facilitates an
emergency exit.
Driveways
Informational Conditions
There are predictable cracks in the driveway that would not necessarily need to be serviced.
Walkways
Informational Conditions
The walkways are in acceptable condition.
Fences & Gates
Informational Conditions
Portions of this property are not fenced or otherwise enclosed, to provide security for children or animals.
Fascia & Trim
Informational Conditions
Sections of the fascia board or wood trim are weathered, and should be serviced to prevent further
deterioration.
Sliding Glass Doors
Informational Conditions
The sliding glass door is tempered and in acceptable condition.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 6
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
Structural
All structures are dependent on the soil beneath them for support, but soils are not uniform. Some that might
appear to be firm and solid can liquefy and become unstable during seismic activity. Also, there are soils that
can expand to twice their volume with the influx of water and move structures with relative ease, raising and
lowering them and fracturing slabs and other hard surfaces. In fact, expansive soils have accounted for more
structural damage than most natural disasters. Regardless, foundations are not uniform, and conform to the
structural standard of the year in which they were built. In accordance with our standards of practice, we identify
foundation types and look for any evidence of structural deficiencies. However, cracks or deteriorated surfaces
in foundations are quite common. In fact, it would be rare to find a raised foundation wall that was not cracked
or deteriorated in some way, or a slab foundation that did not include some cracks concealed beneath the
carpeting and padding. Fortunately, most of these cracks are related to the curing process or to common
settling, including some wide ones called cold-joint separations that typically contour the footings, but others
can be more structurally significant and reveal the presence of expansive soils that can predicate more or less
continual movement. We will certainly alert you to any suspicious cracks if they are clearly visible. However,
we are not specialists, and in the absence of any major defects we may not recommend that you consult with a
foundation contractor, a structural engineer, or a geologist, but this should not deter you from seeking the
opinion of any such expert.
Structural Elements
Identification of Wall Structure
Informational Conditions
The walls are conventionally framed with wooden studs.
Identification of Floor Structure
Informational Conditions
The floor structure consists of a poured slab that could include reinforcing steel.
Identification of Ceiling Structure
Informational Conditions
The ceiling structure consists of standard joists.
Identification of Roof Structure
Informational Conditions
The roof structure consists of a prefabricated truss system.
Slab Foundation
General Comments
Informational Conditions
This residence has a slab foundation. Such foundations vary considerably from older ones that have no
moisture barrier under them and no reinforcing steel within them to newer ones that have both. Our inspection
of slab foundations conforms to industry standards, which is that of a generalist and not a specialist. We check
the visible portion of the stem walls on the outside for any evidence of significant cracks or structural
deformation, but we do not move furniture or lift carpeting and padding to look for cracks or moisture
penetration, and we do not use any of the specialized devices that are used to establish relative elevations and
confirm differential movement. Significantly, many slabs are built or move out of level, but the average person
may not become aware of this until there is a difference of more than one inch in twenty feet, which most
authorities regard as being tolerable.
Many slabs are found to contain cracks when the carpet and padding are removed, including some that contour
the edge and can be quite wide. They typically result from shrinkage and usually have little structural
significance. However, there is no absolute standard for evaluating cracks, and those that are less than 1/4"
and which exhibit no significant vertical or horizontal displacement are generally not regarded as being
significant. Although they typically do result from common shrinkage, they can also be caused by a deficient
mixture of concrete, deterioration through time, seismic activity, adverse soil conditions, and poor drainage,
and if they are not sealed they can allow moisture to enter a residence, and particularly if the residence is
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 7
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
surcharged by a hill or even a slope, or if downspouts discharge adjacent to the slab. However, in the absence
of any major defects, we may not recommend that you consult with a foundation contractor, a structural
engineer, or a geologist, but this should not deter you from seeking the opinion of any such expert, and we
would be happy to refer one.
Method of Evaluation
Informational Conditions
We evaluated the slab foundation on the exterior, by examining the stem walls that project above the footing at
the base of the house walls. The interior portions of the slab, which is also known as the slab floor, have little
structural significance and, inasmuch as they are covered and not visually accessible, it is beyond the scope of
our inspection.
Common Observations
Informational Conditions
The residence has a bolted, slab foundation with no visible or significant abnormalities.
Roof
There are many different roof types, which we evaluate by walking on their surfaces. If we are unable or
unwilling to do this for any reason, we will indicate the method that was used to evaluate them. Every roof will
wear differently relative to its age, the number of its layers, the quality of its material, the method of its
application, its exposure to direct sunlight or other prevalent weather conditions, and the regularity of its
maintenance. Regardless of its design-life, every roof is only as good as the waterproof membrane beneath it,
which is concealed and cannot be examined without removing the roof material, and this is equally true of
almost all roofs. In fact, the material on the majority of pitched roofs is not designed to be waterproof only
water-resistant. However, what remains true of all roofs is that, whereas their condition can be evaluated, it is
virtually impossible for anyone to detect a leak except as it is occurring or by specific water tests, which are
beyond the scope of our service. Even water stains on ceilings, or on the framing within attics, could be old and
will not necessarily confirm an active leak without some corroborative evidence, and such evidence can be
deliberately concealed. Consequently, only the installers can credibly guarantee that a roof will not leak, and
they do. We evaluate every roof conscientiously, and even attempt to approximate its age, but we will not
predict its remaining life expectancy, or guarantee that it will not leak. Naturally, the sellers or the occupants of
a residence will generally have the most intimate knowledge of the roof and of its history. Therefore, we
recommend that you ask the sellers about it, and that you either include comprehensive roof coverage in your
home insurance policy, or that you obtain a roof certification from an established local roofing company.
Composition Shingle Roof
General Comments
Informational Conditions
There are a wide variety of composition shingle roofs, which are comprised of asphalt or fiberglass materials
impregnated with mineral granules that are designed to deflect the deteriorating ultra-violet rays of the sun. The
commonest of these roofs are warranted by manufacturers to last from twenty to twenty-five years, and are
typically guaranteed against leaks by the installer for three to five years. The actual life of the roof will vary,
depending on a number of interrelated factors besides the quality of the material and the method of installation.
However, the first indication of significant wear is apparent when the granules begin to separate and leave
pockmarks or dark spots. This is referred to as primary decomposition, which means that the roof is in decline,
and therefore susceptible to leakage. This typically begins with the hip and ridge shingles and to the field
shingles on the south facing side. This does not mean that the roof needs to be replaced, but that it should be
monitored more regularly and serviced when necessary. Regular maintenance will certainly extend the life of
any roof, and will usually avert most leaks that only become evident after they have caused other damage.
Method of Evaluation
Informational Conditions
We evaluated the roof and its components by walking on its surface.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 8
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
Estimated Age
Informational Conditions
The roof appears to be the same age as the residence, or ___ years old.
Roofing Material
Informational Conditions
The roof is in acceptable condition, but this is not a guarantee against leaks. For a guarantee, you would need
to have a roofing company perform a water-test and issue a roof certification.
Flashings
Informational Conditions
The roof flashings are in acceptable condition.
Gutters & Drainage
Informational Conditions
The roof only has partial gutters and full gutters are recommended for the general welfare of the residence and
its foundation, inasmuch as moisture is a perennial problem.
Chimney
There are a wide variety of chimneys, which represent an even wider variety of the interrelated components
that comprise them. However, there are three basic types, single-walled metal, masonry, and pre-fabricated
metal ones that are commonly referred to as factory-built ones. Single-walled metal ones should not be
confused with factory-built metal ones, and are rarely found in residential use, but masonry and factory-built
ones are a commonplace. Our inspection of them conforms to industry standards, and is that of a generalist
and not a specialist. However, significant areas of chimney flues cannot be adequately viewed during a field
inspection, as has been documented by the Chimney Safety Institute of America, which reported in 1992: "The
inner reaches of a flue are relatively inaccessible, and it should not be expected that the distant oblique view
from the top or bottom is adequate to fully document damage even with a strong light." Therefore, because our
inspection of chimneys is limited to those areas that can be viewed without dismantling any portion of them,
and does not include the use of specialized equipment, we will not guarantee their integrity or drafting ability
and recommend that they be video-scanned before the close of escrow.
Living Room Chimney
General Prefabricated
Informational Conditions
There are a wide variety of pre-fabricated chimneys, which are constructed on site with approved components.
We perform a competent inspection of them, but we are not specialists, and our inspection of them is limited to
those areas that can be viewed without dismantling any portion of them, and we cannot guarantee that any
particular component is the one stipulated for use by the manufacturer. For instance, experience has taught us
that many prefabricated chimneys have been fitted with architectural shrouds that are not approved by the
manufacturer, and which can inhibit drafting and convectional cooling. Therefore, you may wish to have a
specialist evaluate the chimney before the close of escrow.
Chimney Flashings
Informational Conditions
The chimney flashings are in acceptable condition.
Glass Doors
Components and Conditions Needing Service
One of the glass doors on the fireplace is broken, and should be repaired or replaced.
Hearth
Informational Conditions
The hearth is in acceptable condition.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 9
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
Plumbing
Plumbing systems have common components, but they are not uniform. In addition to fixtures, these
components include gas pipes, water pipes, pressure regulators, pressure relief valves, shut-off valves, drain
and vent pipes, and water-heating devices, some of which we do not test if they are not in daily use. The best
and most dependable water pipes are copper, because they are not subject to the build-up of minerals that
bond within galvanized pipes, and gradually restrict their inner diameter and reduce water volume. Water
softeners can remove most of these minerals, but not once they are bonded within the pipes, for which there
would be no remedy other than a re-pipe. The water pressure within pipes is commonly confused with water
volume, but whereas high water volume is good high water pressure is not. In fact, whenever the street
pressure exceeds eighty pounds per square inch a regulator is recommended, which typically comes factory
preset between forty-five and sixty-five pounds per square inch. However, regardless of the pressure, leaks will
occur in any system, and particularly in one with older galvanized pipes, or one in which the regulator fails and
high pressure begins to stress the washers and diaphragms within the various components.
Waste and drainpipes pipes are equally varied, and range from modern ABS ones [acrylonitrile butadiene
styrene] to older ones made of cast-iron, galvanized steel, clay, and even a cardboard-like material that is
coated with tar. The condition of these pipes is usually directly related to their age. Older ones are subject to
damage through decay and root movement, whereas the more modern ABS ones are virtually impervious to
damage, although some rare batches have been alleged to be defective. However, inasmuch as significant
portions of drainpipes are concealed, we can only infer their condition by observing the draw at drains.
Nonetheless, blockages will occur in the life of any system, but blockages in drainpipes, and particularly in main
drainpipes, can be expensive to repair, and for this reason we recommend having them video-scanned. This
could also confirm that the house is connected to the public sewer system, which is important because all
private systems must be evaluated by specialists.
Potable Water Supply Pipes
Water Main Shut-off Location
Informational Conditions
The main water shut-off valve is located in the house side yard.
Pressure Regulators
Informational Conditions
The pressure at the street is under 80psi and a regulator is not required on the plumbing system.
Copper Water Pipes
Informational Conditions
The potable water pipes are in acceptable condition.
Electric Water Heaters
General Comments
Informational Conditions
There are a wide variety of residential electric water heaters that range in capacity from fifteen to one hundred
gallons. They can be expected to last at least as long as their warranty, or from five to eight years, but they will
generally last longer. However, few of them last longer than fifteen or twenty years and many eventually leak.
So it is always wise to have them installed over a drain pan plumbed to the exterior. Also, it is prudent to flush
them annually to remove minerals that include the calcium chloride bi-product of many water softening
systems. The water temperature should be set at a minimum of 110 degrees fahrenheit to kill microbes and a
maximum of 140 degrees to prevent scalding. Also, water heaters can be dangerous if they are not seismically
secured and equipped with a pressure/temperature relief valve and discharge pipe plumbed to the exterior.
Age Capacity & Location
Informational Conditions
Hot water is provided by a 7 year old, 40 gallon water heater that is located in the garage.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 10
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
Water Shut-Off Valve & Connectors
Components and Conditions Needing Service
The water shut-off valve is leaking, and should be repaired.
Relief Valve & Discharge Pipe
Components and Conditions Needing Service
The discharge pipe is plumbed incorrectly to discharge into a drain pan. However, it or the drain pan should be
plumbed to discharge at the exterior and terminate at a point no more than twenty-four inches above grade and
no less than six inches to it. If this is not feasible, the pressure relief valve could be replaced with a Watts 210
valve, which serves the same purpose and meets the same safety requirement. However, a pressure relief
valve must be present elsewhere on the system.
Drip Pan & Overflow Pipe
Informational Conditions
The water heater is equipped with a drip pan and a drain pipe, which is designed to prevent water damage from
a leak. Nevertheless, the water heater should be periodically monitored for any signs of a leak.
Waste & Drainage Systems
General Comments
Informational Conditions
We attempt to evaluate drain pipes by flushing every drain that has an active fixture while observing its draw
and watching for blockages or slow drains, but this is not a conclusive test and only a video-scan of the main
line would confirm its actual condition. However, you can be sure that blockages will occur, usually relative in
severity to the age of the system, and will range from minor ones in the branch lines, or at the traps beneath
sinks, tubs, and showers, to major blockages in the main line. The minor ones are easily cleared, either by
chemical means or by removing and cleaning the traps. However, if tree roots grow into the main drain that
connects the house to the public sewer, repairs could become expensive and might include replacing the entire
main line. For these reasons, we recommend that you ask the sellers if they have ever experienced any
drainage problems, or you may wish to have the main waste line video-scanned before the close of escrow.
Failing this, you should obtain an insurance policy that covers blockages and damage to the main line.
However, most policies only cover plumbing repairs within the house, or the cost of rooter service, most of
which are relatively inexpensive.
Electrical
There are a wide variety of electrical systems with an even greater variety of components, and any one
particular system may not conform to current standards or provide the same degree of service and safety.
What is most significant about electrical systems however is that the national electrical code [NEC] is not
retroactive, and therefore many residential systems do not comply with the latest safety standards. Regardless,
we are not electricians and in compliance with our standards of practice we only test a representative number
of switches and outlets and do not perform load-calculations to determine if the supply meets the demand.
However, in the interests of safety, we regard every electrical deficiency and recommended upgrade as a latent
hazard that should be serviced as soon as possible, and that the entire system be evaluated and certified as
safe by an electrician. Therefore, it is essential that any recommendations that we may make for service or
upgrades should be completed before the close of escrow, because an electrician could reveal additional
deficiencies or recommend some upgrades for which we would disclaim any further responsibility. However, we
typically recommend upgrading outlets to have ground fault protection, which is a relatively inexpensive but
essential safety feature. These outlets are often referred to as GFCI's, or ground fault circuit interrupters and,
generally speaking, have been required in specific locations for more than thirty years, beginning with
swimming pools and exterior outlets in 1971, and the list has been added to ever since: bathrooms in 1975,
garages in 1978, spas and hot tubs in 1981, hydro tubs, massage equipment, boat houses, kitchens, and
unfinished basements in 1987, crawlspaces in 1990, wet bars in 1993, and all kitchen countertop outlets with
the exception of refrigerator and freezer outlets since 1996. Similarly, AFCI's or arc fault circuit interrupters,
represent the very latest in circuit breaker technology, and have been required in all bedroom circuits since
2002. However, inasmuch as arc faults cause thousands of electrical fires and hundreds of deaths each year,
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 11
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
we categorically recommend installing them at every circuit as a prudent safety feature.
Main Panel
General Comments
Informational Conditions
National safety standards require electrical panels to be weatherproof, readily accessible, and have a minimum
of thirty-six inches of clear space in front of them for service. Also, they should have a main disconnect, and
each circuit within the panel should be clearly labeled. Industry standards only require us to test a
representative number of accessible switches, receptacles, and light fixtures. However, we attempt to test
every one that is unobstructed, but if a residence is furnished we will obviously not be able to test each one.
Service Entrance
Informational Conditions
The main conductor lines are underground, or part of a lateral service entrance. This is characteristic of modern
electrical services but, inasmuch as the service lines are underground and cannot be seen, they are not
evaluated as part of our service.
Panel Size & Location
Informational Conditions
The residence is served by a ___ amp, 220 volt panel, located inside the garage.
Main Panel Observations
Informational Conditions
The panel and its components have no visible deficiencies.
Circuit Breakers
Informational Conditions
There are no visible deficiencies with the circuit breakers.
Various circuits are not labeled, which is recommended.
Grounding
Informational Conditions
The panel is grounded to a driven rod.
Heat-A/C
The components of most heating and air-conditioning systems have a design-life ranging from ten to twenty
years, but can fail prematurely with poor maintenance, which is why we apprise you of their age whenever
possible. We test and evaluate them in accordance with the standards of practice, which means that we do not
dismantle and inspect the concealed portions of evaporator and condensing coils, the heat exchanger, which is
also known as the firebox, electronic air-cleaners, humidifiers, ducts and in-line duct-motors or dampers. We
perform a conscientious evaluation of both systems, but we are not specialists. However, even the most
modern heating systems can produce carbon monoxide, which in a sealed or poorly ventilated room can result
in sickness, debilitating injury, and even death. Therefore, in accordance with the terms of our contract, it is
essential that any recommendations that we make for service or a second opinion be scheduled before the
close of escrow, because a specialist could reveal additional defects or recommend further upgrades that could
affect your evaluation of the property, and our service does not include any form of warranty or guarantee.
HVAC Split Systems
Age & Location
Informational Conditions
Central heat and air-conditioning are provided by a single split-system, consisting of a 7 year-old furnace with
an evaporator coil that is located the garage, and a 7 year-old condensing coil that is located in side yard.
Evaporator Coil
Components and Conditions Needing Service
Ice forms on the refrigerant lines, which has multiple causes ranging from closed off registers and clogged
filters to low refrigerant, and the system should be serviced.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 12
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
Condensate Drainpipe
Informational Conditions
The condensate drainpipe discharges correctly outside the residence.
Differential Temperature Readings
Informational Conditions
The air-conditioning responded and achieved an acceptable differential temperature split between the air
entering the system and that coming out, of eighteen degrees or more.
Registers
Informational Conditions
The registers are reasonably clean and functional.
Flexible Ducting
Informational Conditions
The ducts have no visible deficiencies. They are a modern flexible type that are comprised of an outer plastic
sleeve and a clear inner liner that contains fiberglass insulation.
Living
Our inspection of living space includes the visually accessible areas of walls, floors, cabinets and closets, and
includes the testing of a representative number of windows and doors, switches and outlets. However, we do
not evaluate window treatments, or move furniture, lift carpets or rugs, empty closets or cabinets, and we do
not comment on cosmetic deficiencies. We may not comment on the cracks that appear around windows and
doors, or which follow the lines of framing members and the seams of drywall and plasterboard. These cracks
are a consequence of movement, such as wood shrinkage, common settling, and seismic activity, and will often
reappear if they are not correctly repaired. Such cracks can become the subject of disputes, and are therefore
best evaluated by a specialist. Similarly, there are a number of environmental pollutants that we have already
elaborated upon, the specific identification of which is beyond the scope of our service but which can become
equally contentious. In addition, there are a host of lesser contaminants, such as that from moisture penetrating
carpet-covered cracks in floor slabs, as well as odors from household pets and cigarette smoke that can
permeate walls, carpets, heating and air conditioning ducts, and other porous surfaces, and which can be
difficult to eradicate. However, inasmuch as the sense of smell adjusts rapidly, and the sensitivity to such odors
is certainly not uniform, we recommend that you make this determination for yourself, and particularly if you or
any member of your family suffers from allergies or asthma, and then schedule whatever remedial services
may be deemed necessary before the close of escrow.
Main Entry
Doors
Informational Conditions
The doors are functional.
The doorbell does not work, and should be serviced.
The keyed deadbolt could prevent or impede an emergency exit, and should be replaced with a safer latch
type.
Flooring
Components and Conditions Needing Service
The floor is out of level. We can elaborate, but this condition should be evaluated by a structural engineer or a
foundation contractor.
Walls & Ceiling
Informational Conditions
The walls and ceiling have typical stress fractures, which have resulted from movement, and which will usually
reappear if they are not repaired correctly.
Single-Glazed Windows
Informational Conditions
The windows are functional.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 13
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
Closets
Components and Conditions Needing Service
The closet door needs to be shaved or trimmed to close easily, and should be serviced.
Lights
Functional Components and Conditions
The lights are functional.
Living Room
Outlets
Components and Conditions Needing Service
An outlet has an open ground, and should be serviced.
Dining Room
No Recommended Service
Informational Conditions
We have evaluated the dining room, and found it to be in acceptable condition.
Family Room
No Recommended Service
Informational Conditions
We have evaluated the family room, and found it to be in acceptable condition.
Kitchen
We test kitchen appliances for their functionality, and cannot evaluate them for their performance nor for the
variety of their settings or cycles. However, if they are older than ten years, they may well exhibit decreased
efficiency. Also, many older gas and electric ranges are not secured and can be easily tipped, particularly when
any weight is applied to an open range door, and all such appliances should be confirmed to be secure.
Regardless, we do not inspect the following items: free-standing appliances, refrigerators, trash-compactors,
built-in toasters, coffee-makers, can-openers, blenders, instant hot-water dispensers, water-purifiers,
barbecues, grills or rotisseries, timers, clocks, thermostats, the self-cleaning capability of ovens, and concealed
or countertop lighting, which is convenient but often installed after the initial construction and not wired to
national electrical standards.
Kitchen
Flooring
Components and Conditions Needing Service
There are cracks in the tiles, which you should view for yourself. They are likely to have been caused by
movement or an insubstantial mortar base, but you may wish to seek the opinion of a specialist.
Walls & Ceiling
Functional Components and Conditions
The walls and ceiling are in acceptable condition.
Sink & Countertop
Components and Conditions Needing Service
The island, or its countertop, is not secure. This could pose a safety threat to children, and should be secured.
Cabinets
Informational Conditions
The cabinets have typical, cosmetic damage, or that which is commensurate with their age.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 14
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
Faucet
Components and Conditions Needing Service
The faucet is loose, and should be secured.
Garbage Disposal
Components and Conditions Needing Service
The electrical connection to the garbage disposal is substandard. The disposal should be powered by an
approved appliance cord, or be hardwired.
Electric Range
Informational Conditions
The range is not equipped with an anti-tip device, which prevents the range from tipping, or its contents from
spilling, should a child attempt to climb on it or its open door. This is a recommended safety feature that should
be installed, and particularly if small children occupy or visit the residence.
Dishwasher
Functional Components and Conditions
The dishwasher is functional.
Exhaust Fan or Downdraft
Informational Conditions
The exhaust fan is functional and a type that vents internally.
Built-in Microwave
Functional Components and Conditions
The built-in microwave is functional but we did not test it for leakage, which would require a specialized
instrument.
Outlets
Functional Components and Conditions
The outlets that were tested are functional and include ground-fault protection.
Attic
In accordance with our standards, we do not attempt to enter attics that have less than thirty-six inches of
headroom, are restricted by ducts, or in which the insulation obscures the joists and thereby makes mobility
hazardous, in which case we would inspect them as best we can from the access point. In regard to evaluating
the type and amount of insulation on the attic floor, we use only generic terms and approximate measurements,
and do not sample or test the material for specific identification. Also, we do not disturb or move any portion of
it, and it may well obscure water pipes, electrical conduits, junction boxes, exhaust fans, and other components.
Primary Attic
Attic Access Location
Informational Conditions
The attic can be accessed through a hatch in the garage.
Method of Evaluation
Informational Conditions
We evaluated the attic by direct access.
Framing
Informational Conditions
The roof framing consists of a factor- built truss system, comprised of components called chords, webs, and
struts that are connected by wood or metal gussets nailed or glued in place. Each component of the truss is
designed for a specific purpose, and cannot be removed or modified without compromising the integrity of the
entire truss. The lowest component, which is called the chord and to which the ceiling is attached, can move by
thermal expansion and contraction and cause creaking sounds, which are more pronounced in the mornings
and evenings along with temperature changes. Such movement has no structural significance, but can result in
small cracks or divots in the drywall or plaster.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 15
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
Ventilation
Informational Conditions
Ventilation is provided by a combination of eave, dormer, turbine, or gable vents, and should be adequate.
Electrical
Components and Conditions Needing Service
There is an open electrical junction box, which should be sealed so that any arching or sparking would be
contained within the box.
Plumbing Vents
Informational Conditions
The drainpipe vents that are fully visible are in acceptable condition.
Batt Insulation
Informational Conditions
The attic floor is insulated with three-inches of foil-faced, batt, insulation. Current standards call for nine and
even twelve-inches of insulation, and you may wish to consider adding more. Regardless. The foil on this
material can prove to be hazardous in conjunction with electricity, and any person entering the attic to perform
electrical work should be suitably cautioned.
Bedrooms
In accordance with the standards of practice, our inspection of bedrooms includes the visually accessible areas
of walls, floors, cabinets and closets, and includes the testing of a representative number of windows and
doors, switches and outlets. We evaluate windows to ensure that they meet light and ventilation requirements
and facilitate an emergency exit or egress, but we do not evaluate window treatments, nor move furniture, lift
carpets or rugs, empty closets or cabinets, and we do not comment on common cosmetic deficiencies.
Master Bedroom
Doors
Components and Conditions Needing Service
The door handle needs to be serviced to work smoothly.
Walls & Ceiling
Informational Conditions
The walls and ceiling are in acceptable condition.
Closets
Components and Conditions Needing Service
The closet door needs to be shaved or trimmed to close easily.
Smoke Detector
Informational Conditions
The smoke detector is functional, but should be checked periodically.
1st Guest Bedroom
Location
Informational Conditions
The first guest bedroom is located south front
No Recommended Service
Informational Conditions
We have evaluated the bedroom, and found it to be in acceptable condition.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 16
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
2nd Guest Bedroom
Location
Informational Conditions
The second guest bedroom is located south back
No Recommended Service
Informational Conditions
We have evaluated the bedroom, and found it to be in acceptable condition.
Bathrooms
In accordance with industry standards, we do not comment on common cosmetic deficiencies, and do not
evaluate window treatments, steam showers, and saunas. More importantly, we do not leak-test shower pans,
which is usually the responsibility of a termite inspector. However, because of the possibility of water damage,
most termite inspectors will not leak-test second floor shower pans without the written consent of the owners or
occupants.
Master Bathroom
Size and Location
Informational Conditions
The master bathroom is a full, and is located adjacent to the master bedroom.
No Recommended Service
Informational Conditions
We have evaluated the master bathroom, and found it to be in acceptable condition.
Main Hallway Bathroom
Size and Location
Informational Conditions
The main hallway bathroom is a full, and located off the main hallway.
Flooring
Informational Conditions
The floor is worn or cosmetically damaged, which you should view for yourself.
Sink Countertop
Informational Conditions
There is a separation between the sink and the countertop, which should be sealed to forestall moisture
intrusion between the cabinet and the wall.
Laundry
In accordance with industry standards, we do not test clothes dryers, nor washing machines and their water
connections and drainpipes. However, there are two things that you should be aware of. The water supply to
washing machines is usually left on, and their hoses can leak or burst under pressure and continue to flow.
Therefore, we recommend replacing the rubber hose type with newer braided stainless steel ones that are
much more dependable. You should also be aware that the newer washing machines discharge a greater
volume of water than many of the older drainpipes can handle, which causes the water to back up and
overflow, and the only remedy would be to replace the standpipe and trap with one that is a size larger.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 17
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
Laundry Room
No Recommended Service
Informational Conditions
We have evaluated the laundry room, and found it to be in acceptable condition.
Garage
It is not uncommon for moisture to penetrate garages, because their slabs are on-grade. Evidence of this is
typically apparent in the form of efflorescence, or salt crystal formations, that result when moisture penetrates
the concrete slab or sidewalls. This is a common with garages that are below grade, and some sidewalls are
even cored to relieve the pressure that can build up behind them, and which actually promotes drainage
through the garage. Also, if there is living space above the garage, that space will be seismically vulnerable.
Ideally, the columns and beams around the garage door will be made of structural steel, but in many residences
these components are made of wood but could include some structural accessories, such as post-straps and
hold-downs, and plywood shear paneling. However, we are not an authority in such matters, and you may wish
to discuss this further with a structural engineer. In addition, and inasmuch as garage door openings are not
standard, you may wish to measure the opening to ensure that there is sufficient clearance to accommodate
your vehicles.
Double-Car Garage
Parking Space
Informational Conditions
The parking space has been restricted by the addition of storage shelves or a workbench. Therefore, it would
be prudent for you to see that the parking space is adequate to accommodate your vehicles.
Slab Floor
Informational Conditions
The slab floor is cracked, but not load-bearing. Such cracks are common and result as a consequence of the
curing process, seismic activity, ordinary settling, or the presence of expansive soils, but are not structurally
threatening. We can elaborate, but you may wish to have a structural engineer confirm this.
Walls & Ceiling
Components and Conditions Needing Service
There is evidence of moisture intrusion in the garage. However, it is not uncommon to find such evidence in the
form of efflorescence, or salt crystal formations, on the walls and slab of a garage. Garages are built on-grade,
and most will be subject to some degree of moisture intrusion when it is raining. In spite of this, many older
garages will not have a moisture barrier beneath the slab and, if they are below grade, the walls may not have
been treated to resist moisture. However, you may wish to ask the sellers about this condition or have it
evaluated by a grading and drainage contractor.
Firewall Separation
Components and Conditions Needing Service
The voids in the garage firewall must be repaired, in order to maintain the necessary firewall separation
between the garage and the residence.
The voids in the ceiling firewall must be repaired, in order to maintain the necessary firewall separation
between the garage and the residence.
A pull-down ladder assembly in the garage ceiling violates the necessary firewall separation between the
garage and the living quarters. Its hatch cover should be sheathed in metal, or the wall of the residence beyond
it must be plastered or dry-walled.
Entry Door Into the House
Components and Conditions Needing Service
The house entry door is not identified as being fire-rated and must be, to maintain the necessary firewall
separation between a garage and living quarters, and will need to be replaced.
Garage Side Door
Components and Conditions Needing Service
The base of the garage side door is moisture damaged and delaminating, and should be repaired.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 18
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 19
AFFILIATIONS AND CERTIFICATIONS
ICBO Certified Building Inspector # _______________
ICBO Certified Mechanical Inspector # _____________
ICBO Certified Combination Dwelling Inspector # _________
IAPMO Certified Mechanical Inspector #_______
California Real Estate Inspection Association "C.P.I." # _______
Structural Pest Inspector License #__________
AHERA Certified Building Inspector #__________
Inspector
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 20
REPORT CONCLUSION
Congratulations on the purchase of your new home. Inasmuch as we never know who will be occupying or
visiting a property, whether it be children or the elderly, we ask you to consider following these general safety
recommendations: install smoke and carbon monoxide detectors; identify all escape and rescue ports; rehearse
an emergency evacuation of the home; upgrade older electrical systems by at least adding ground-fault outlets;
never service any electrical equipment without first disconnecting its power source; safety-film all non-tempered
glass; ensure that every elevated window and the railings of stairs, landings, balconies, and decks are
child-safe, meaning that barriers are in place or that the distance between the rails is not wider than three
inches; regulate the temperature of water heaters to prevent scalding; make sure that goods that contain
caustic or poisonous compounds, such as bleach, drain cleaners, and nail polish removers be stored where
small children cannot reach them; ensure that all garage doors are well balanced and have a safety device,
particularly if they are the heavy wooden type; remove any double-cylinder deadbolts from exterior doors; and
consider installing child-safe locks and alarms on the exterior doors of all pool and spa properties.
We are proud of our service, and trust that you will be happy with the quality of our report. We have made
every effort to provide you with an accurate assessment of the condition of the property and its components
and to alert you to any significant defects or adverse conditions. However, we may not have tested every
outlet, and opened every window and door, or identified every minor defect. Also because we are not
specialists or because our inspection is essentially visual, latent defects could exist. Therefore, you should not
regard our inspection as conferring a guarantee or warranty. It does not. It is simply a report on the general
condition of a particular property at a given point in time. Furthermore, as a homeowner, you should expect
problems to occur. Roofs will leak, drain lines will become blocked, and components and systems will fail
without warning. For these reasons, you should take into consideration the age of the house and its
components and keep a comprehensive insurance policy current. If you have been provided with a home
protection policy, read it carefully. Such policies usually only cover insignificant costs, such as that of rooter
service, and the representatives of some insurance companies can be expected to deny coverage on the
grounds that a given condition was preexisting or not covered because of what they claim to be a code violation
or a manufacture's defect. Therefore, you should read such policies very carefully, and depend upon our
company for any consultation that you may need.
Thank you for taking the time to read this report, and call us if you have any questions or observations
whatsoever. We are always attempting to improve the quality of our service and our report, and we will
continue to adhere to the highest standards of the real estate industry and to treat everyone with kindness,
courtesy, and respect.
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Inspection Narratives - Page 21
Inspection Address: ,
Inspection Date/Time: 5/16/2006 9:00 am to 12:30 pm
_____________________________________________________________________________________________
TABLE OF CONTENTS
CONFIDENTIAL INSPECTION REPORT 1
GENERAL INFORMATION 2
SCOPE OF WORK 3
Exterior 5
Site & Other Observations 5
Grading & Drainage 5
House Wall Finish 6
Exterior Components 6
Structural 7
Structural Elements 7
Slab Foundation 7
Roof 8
Composition Shingle Roof 8
Chimney 9
Living Room Chimney 9
Plumbing 10
Potable Water Supply Pipes 10
Electric Water Heaters 10
Waste & Drainage Systems 11
Electrical 11
Main Panel 12
Heat-A/C 12
HVAC Split Systems 12
Living 13
Main Entry 13
Living Room 14
Dining Room 14
Family Room 14
Kitchen 14
Kitchen 14
Attic 15
Primary Attic 15
Bedrooms 16
Master Bedroom 16
1st Guest Bedroom 16
2nd Guest Bedroom 17
Bathrooms 17
Master Bathroom 17
Main Hallway Bathroom 17
Laundry 17
Laundry Room 18
Garage 18
Double-Car Garage 18
Certifications and Affiliations 20
Report Conclusion 21
_____________________________________________________________________________________________
This report has been produced in accordance with our signed contract and is subject to the terms and conditions agreed upon therein.
All printed comments and the opinions expressed herein are those of the Inspection Company.
Table of Contents - Page 1
|
|
|
|
|
 |